Function: Designed to support CPVC pipe horizontally from the side or bottom of beam. Fig. 070 can only be used as a guide on top of beam or on vertical piping. It also acts as a restrainer to prevent the thrust of a sprinkler head during activation when mounted on top of structure. Fig. 070 may be installed onto wood using supplied fasteners or into, minimum 20 gauge, steel using two 1/4" x l" tek type screws. Features flared edges to protect piping as it slides through the installed fitting and retaining dimples to allow for easy installation onto pipe.

Material: Carbon steel

Finish: Pre-galvanized

Ordering: Specify pipe size and model number.

Approvals: Underwriters Laboratories listed in the U.S. (UL) and Canada(CUL).


Function: Designed to support CPVC pipe horizontally from the side of a beam. Fig. 075 must be installed with the mounting tab oriented over top of piping on the side of a beam. It can only be used as a guide on top of beam or on vertical piping. Fig. 075 may be installed onto wood using supplied fasteners or into, minimum 20 gauge, steel using one 1/4" x l" tek type screw. Features flared edges to protect piping as it slides through the installed fitting.

Material: Carbon steel

Finish: Pre-galvanized

Ordering: Specify pipe size and model number.

Approvals: Underwriters Laboratories listed in the U.S. (UL) and Canada (CUL).


Function: Designed to support CPVC pipe horizontally from the side or bottom of beam, or composite wood joists with a minimum of 3/8" web thickness. It can only be used as a guide on top of beam or on vertical piping. Fig. 076 may be installed onto wood using supplied fasteners or into, minimum 18 gauge, steel using two 1/4" x l" tek type screws. Features flared edges to protect piping as it slides through the installed fitting.

Material: Carbon steel

Finish: Pre-galvanized

Ordering: Specify pipe size and model number.

Approvals: Underwriters Laboratories listed in the U.S. (UL) and Canada (CUL).


Function: Designed to support CPVC pipe horizontally from the side or bottom of beam. Fig. 077 can only be used as a guide on top of beam or on vertical piping. It also acts as a restrainer to prevent the thrust of a sprinkler head during activation when mounted on top of structure. Fig. 077 may be installed onto wood using supplied fasteners or into, minimum 20 gauge, steel using two 1/4" x l" tek type screws. Features flared edges to protect piping as it slides through the installed fitting and retaining dimples to allow for easy installation onto pipe.

Material: Carbon steel

Finish: Pre-galvanized

Ordering: Specify pipe size and model number.

Approvals: Underwriters Laboratories listed in the U.S. (UL) and Canada (CUL).