055
Surge Restraint
Function:
Designed to restrict the upward movement of activated fire sprinkler systems. Grips ring hanger (NOT THE NUT) and allows for fine tuning adjustments. Listed for use with PHD Manufacturing, Inc. Fig. 141 Swivel Ring Hangers only.
Material:
Spring steel
Finish:
Powder coated
Ordering:
Specify figure number.
Install:
Installs easily before or after pipe installation and without tools. Simply clip Fig. 055 onto Fig. 141 Swivel Ring Hanger and run the hanger rod down to the bottom plate surface to ensure proper restraint.
Approvals:
Underwriters' Laboratories Listed in the U.S. (UL) and Canada (CUL).
141, 141F, 151 & 151F
NFPA Swivel Ring Hangers or
Swivel Ring Hangers
Function:
Designed for the suspension of non-insulated stationary pipe lines. The knurled insert nut allows for vertical adjustment after installation. Fig. 141 and 141F knurled insert nut is tapped to NFPA reduced rod size standards. Fig. 141F and 151F have a layer of felt which separates the pipe from the hanger to reduce vibration and sound. Figure 141 sizes 3/4" through 2" are supplied with PHD's "WINGSERT
®
" (Patent Pending) to retain the knurled insert in the hanger until it is installed.
Material:
Low carbon steel
Finish:
Pre-galvanized
Ordering:
Specify pipe size and figure number.
Fig. 141 NFPA Swivel Ring Hanger Pre-galvanized
Fig. 141F NFPA Swivel Ring Hanger Pre-galvanized with Felt Lining
Fig. 151 Swivel Ring Hanger Pre-galvanized
Fig. 151F Swivel Ring Hanger Pre-galanized with Felt Lining
Approvals:
Complies with Federal Specification A-A-1192A (Type 10) and Manufacturers’ Standardization Society ANSI/SP-69 and SP-58 (Type 10).
Fig. 141 & 141F - Underwriters’ Laboratories Listed in the U.S. (UL), Canada (CUL), and Factory Mutual Approved for sizes 3/4" to 8".
Fig. 151 & 151F - Underwriters Laboratories Listed in the U.S. (UL) and Factory Mutual Approved for all sizes.
152, 153 & 154
Copper Tubing & PVC Coated
Swivel Ring Hangers
Function:
Fig. 152 & 154: Designed for the suspension of non-insulated stationary copper tubing. The knurled insert allows for vertical adjustment after installation. Fig. 153: Designed for the suspension of non-insulated stationary pipe lines. Frequently used with aluminum, glass, plastic, brass or copper pipe lines. The PVC coating on Fig. 153 & 154 protects the tubing from contact with the metal surface of the hanger.
Material:
Low carbon steel
Finish:
Copper color epoxy finish, pre-galvanized with PVC coating, or copper color epoxy finish with PVC coating
Ordering:
Specify tube size and figure number.
Fig. 152 Copper Tubing Swivel Ring Copper Color Epoxy Finish
Fig. 153 PVC Coated Swivel Ring Pre-galvanized
Fig. 154 Copper Tubing Swivel Ring Copper Color Epoxy Finish with PVC Coating
Approvals:
Complies with Federal Specification A-A-1192A (Type 10) and Manufacturers’ Standardization Society ANSI/SP-69 and SP-58 (Type 10).
Fig. 153 - Underwriters’ Laboratories Listed in the U.S. (UL) and Factory Mutual Approved for sizes 3/4" to 8".
155
Adjustable Swivel Ring Hanger
with Secured Insulation Shield
Function:
Designed for the suspension of insulated pipe lines. Fig 155 is a combination of our Fig. 160 shield welded to a Fig. 151 hanger, which ensures that the shield will be installed in conjunction with the hanger. Fig. 155 allows vertical adjustment after installation and offers maximum protection from crushing of the insulation by the hanger.
Material:
Low carbon steel
Finish:
Pre-galvanized
Ordering:
Specify size number and figure number.
160
Self Centering Insulation Shield
Function:
Designed to provide maximum protection to the insulation. The centering ribs are spaced to center the hanger on the shield, providing equal load distribution. The shield is furnished with flared ends to prevent it from cutting into the insulation.
Material:
Low carbon steel, available in stainless steel
Finish:
Pre-galvanized
Ordering:
Specify shield number and figure number.
170
Insulation Protection Shield
Function:
Designed for use in the suspension of insulated pipe lines to protect the insulation from being crushed by the hanger.
Material:
Low carbon steel, available in stainless steel
Finish:
Pre-galvanized.
Ordering:
Specify shield number and figure number.
Approvals:
Complies with Federal Specification A-A-1192A (Type 40) and Manufacturers’ Standardization Society ANSI/SP-69 and SP-58 (Type 40).
180, 180F, 181, 182 & 183
Band Hangers or Copper Tubing Band Hanger
Function:
Designed for the suspension of non-insulated stationary pipe lines. Fig. 180F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. The PVC coating on Fig. 183 protects the pipe from the metal surface of the hanger. Fig. 182 is designed for the suspension of non-insulated stationary copper tubing. When proper adjustment has been obtained, the hanger should be locked in place with an upper locknut.
Material:
Low carbon steel, Fig. 180 and 180F available in stainless steel
Finish:
Plain, electro-galvanized, copper color epoxy finish, or plain with PVC coating
Ordering:
Specify pipe size and figure number.
Fig. 180 Band Hanger Plain
Fig. 180F Band Hanger Felt Lined
Fig. 181 Band Hanger Electro-galvanized
Fig. 182 Copper Tubing Band Hanger Copper Color Epoxy Finish
Fig. 183 Band Hanger Plain with PVC Coating
Approvals:
Complies with Federal Specification A-A-1192A (Type 7) and Manufacturers’ Standardization Society ANSI/SP-69 and SP-58 (Type 7).
Shield
Selection Guide